Architectural Design – Construction (repeatable)
- Data provided by BKF Washes Touchless Sp. z o. o.
- architecture design
- construction project
- Internal electrical installation project
- design of internal sanitary installations
Land development project
- Land development project
- application for zoning decisions and land development (Municipal Office)
- terms of reference for a preliminary connections: electrical, gas, water – sewage
- order with the current plan situational surveyor – land survey elevation a minimum of 2 holes (geotechnician)
-
Design work – done by the Investor
- and development board (made in duplicate)
- Coordination board network (folded arrangement Documentation Department)
- road project
- design connections: electrical, gas, water – sewage
- reconciliation of all projects along with the architectural design – building (BKF) with sanel, BHP, P-Fire.,
- experts
- submission of a construction project (which contains all of the above information) to the competent authority in order to obtain a building permit
- attached to the zoning decision provides BKF
The demand for media
Essential requirements for connection of the media in their demand and consumption.
Nr of Stands |
Power connection |
Power supply – technics |
Power supply – lightening |
Water consumption |
Water pressure |
Boiler power |
Gas (type H 20mbar) consumption |
2 |
3 ACN 400 V / 50 Hz |
12 kW -30 A |
10 x 58W = 580 W |
1.8 m³/h |
4-6 bar |
55 kW |
6 m³/h |
3 |
3 ACN 400 V / 50 Hz |
15 kW – 35 A |
14 x 58W = 812 W |
2.5 m³/h |
4-6 bar |
70 kW |
8 m³/h |
4 |
3 ACN 400 V / 50 Hz |
20 kW – 50 A |
18 x 58W = 812 W |
3.4 m³/h |
4-6 bar |
85 kW |
10 m³/h |
5 |
3 ACN 400 V / 50 Hz |
22 kW – 63 A |
22 x 58W = 1276W |
4 m³/h |
4-6 bar |
105 kW |
13 m³/h |
6 |
3 ACN 400 V / 50 Hz |
25 kW – 63 A |
26 x 58W = 1508 W |
5 m³/h |
4-6 bar |
140 kW |
16 m³/h |
7 |
3 ACN 400 V / 50 Hz |
28 kW – 80 A |
26 x 58W = 1508 W |
5.8 m³/h |
4-6 bar |
170 kW |
20 m³/h |
8 |
3 ACN 400 V / 50 Hz |
32 kW – 100 A |
34 x 58W = 1972 W |
6.5 m³/h |
4-6 bar |
200 kW |
24 m³/h |
vacuum cleaner |
two-stand vacuum cleaner consumes additionally 4,5kW |